A reference from uviblox GmbH. More references from uviblox GmbH

Odor reduction of exhaust air from thick sludge loading

Wastewater treatment plant – Berliner Wasserbetriebe Schönerlinde

Treated media: Municipal wastewater, Air

Flow rate: 3.000 (m3/h)

Substances: Odors, VOC

Processes: Activated Carbon

Commissioning: 2021

KF Company: uviblox GmbH

Ref uviblox Schoenerlinde AKF AM

Cause

At the sewage treatment plant in Schönerlinde, thick sludge from the wastewater treatment process is loaded onto trucks for further transport. In the process, odours are emitted, which are mainly caused by hydrogen sulphide being released. In order to eliminate the odour emissions that arise, BWB commissioned uviblox with an exhaust air extraction and cleaning system.

Exhaust air purification system uviblox® FOX

The system consists of two activated carbon tanks with a bulk volume of 2 m³ each, which treat a volume flow of 3,000 m³/h of exhaust air. In addition to the construction and commissioning of the exhaust air extraction and purification, uviblox was also commissioned with regular maintenance and the exchange of activated carbon.

Contact person at uviblox GmbH

Do you have any questions about our services. Then we look forward to your contact request!

Lothar Kratt
Manager